Comparison of Different Methods of Temperature Measurement in Pediatric Patients

ZHANG Guo-di,HUANG Qun-xian,ZHANG Yuan,ZHANG Wen-jing,WANG Xiao-hua,LI Ying,WANG Ye,YUAN You-di
DOI: https://doi.org/10.3969/j.issn.1008-9993.2010.19.013
2010-01-01
Abstract:Objective To investigate the possibility of using tympanic membrane infrared thermometer(ear thermometer) on body temperature measurement in clinical practice.Methods A total of 860 pediatric patients who were admitted to the hospital from September 2008 through May 2009 were involved with convenience sampling method.The aural temperature of each child was measured using ear thermometers and the results were compared to their corresponding axillary and rectal temperatures taken with conventional mercury in glass thermometer.Results The randomized block analysis of variance between the comparison among the aural,axillary and rectal temperatures showed significant differences(P<0.05).Further comparison found that there was no significant difference between the tympanic temperature and rectal temperature(t1=-0.138,P>0.05).While significant differences were observed among the aural,axillary and rectal temperatures(t2=-0.0360,t3=-0.0498,P<0.05).The measuring time for aural,axillary and rectal temperatures were 10 min,3 s,3 min,respectively.Conclusion As a more efficient and secure clinical method for temperature measurement,ear thermometers can replace mercury thermometers in further clinical practice.