Longitudinal Distribution of Ph in Preparative Electrophoresis in a Multicompartment Electrolyzer

J Wang,Z Liu,FX Ding,NJ Yuan
DOI: https://doi.org/10.1080/01496399909353763
IF: 2.799
1999-01-01
Separation Science and Technology
Abstract:Generating an expected longitudinal pH distribution is of essential importance for achieving high resolution in an electrophoresis process conducted in a multicompartment electrolyzer. A simulation of the longitudinal distribution of pH in a multicompartment electrolyzer is proposed on the basis of mass transfer analysis and electrolysis equilibrium of the electrolytes. Selection of the operating conditions to establish an expected pH distribution with a conventional electrolyte rather than an ampholyte can thus be accomplished according to the simulation results. Numerical solution of this model is developed on the basis of the Gear method. The calculated results agree well with the experimental data in a wide range of operation conditions including applied potential, sample loading flow rate, and protein concentration in solution. This model may also be applied to other ampholyte-free electrophoresis processes conducted in a membrane-spaced multicompartment electrolyzer.
What problem does this paper attempt to address?