Animal SPECT/CT imaging and radiation dosimetry of~(99m)Tc-HYNIC-TOC

JIANG Jin-jin,XU Xiao-ping,ZHANG Jian-ping,XU Jun-yan,ZHENG Yu-jia,BAO Xiao
2013-01-01
Abstract:Objective To investigate the distribution of 99mTc-HYNIC-TOC in normal mice and its imaging features in the somatostatin receptor(SSTR)-positive nude mice bearing pancreatic tumor(AR42J) as well as toxicity, radiation dose and radiation assessment. Methods Mice were injected with 99mTc-HYNIC-TOC through tail vein and killed respectively at 0.5, 1, 2, 4, 6 h after injection. The radioactive counting of different organs were determined and converted to standard distribution in humans, and then the radiation and absorbed doses of 99mTc-HYNIC-TOC in human organs and whole body were calculated with OLINDA/EXM software. Serial animal SPECT/CT scans were acquired 2 and 4 h after injection of 99mTc-HYNIC-TOC(0.2 mL/1 mCi) in nude mice bearing AR42J tumor. Results The blood radioactivity decreased rapidly and the tracer excreted mostly via the kidneys and urinary system in normal mice. SSTR-positive nude mice bearing AR42J tumor was imaged clearly 2 h after injection when the ratio of tumor to non-tumor was up to 7.1. The study of radiation dose demonstrated that the intestine absorbed the most body radiation which was 6.40E-03μGy/MBq, and the effective dose was 4.59μSv/MBq. Conclusion 99mTc-HYNIC-TOC is a promising and safe tracer for SSTR-positive tumor imaging.
What problem does this paper attempt to address?