Standardized Method for Measuring Stenosis of Middle Cerebral Artery by Magnetic Resonance Angiography

李大胜,谷春,牛学明,张媛,高树明,张芳,屈辉
DOI: https://doi.org/10.3969/j.issn.1000-0313.2007.10.006
2007-01-01
Abstract:Objective:Applied a standardized method for measuring the stenosis of middle cerebral artery by MRA.Methods:46 stenosis M1 of middle cerebral arteries of 34 patients were diagnosing by TCD,2 radiologists measured the stenosis on MRA by a standardized method as follows:rate of stenosis=[1-(Dstenosis/Dnormal)]×100%,where the D stenosis=the diameter of the artery M1 at the site of the most severe stenosis and Dnormal=the diameter of the proximal normal artery,if the proximal segment was diseased,contiguous sites were chosen to measure Dnormal,and distal artery (second choice),feeding artery (third choice).Results:Between 2 radiologists the choice of Dnormal and percent stenosis measuring result were analysis by two independent sample t-test,P0.05.The average of percent stenosis and the Vs of TCD were analysis by liner regression,and the coefficient of determination R2=0.55.Conclusion:The method shows good intraobserver agreements for measurement of middle cerebral on MRA.If validated in subsequent studies,this method may serve as a standard for the measurement of percent stenosis of an intracranial artery by MRA.
What problem does this paper attempt to address?