Cooling Structure Design for Turbine BladesⅢ:Conjugate Heat Transfer Analysis

CHI Zhong-Ran,WEN Feng-Bo,WANG Song-Tao,FENG Guo-Tai
2011-01-01
Journal of Engineering Thermophysics
Abstract:Three-dimensional conjugated heat transfer analysis is applied during detailed design of blade cooling structure.The calculate domain 3-D models are built with the help of parameterized design method so that models contain detailed geometrical feature and of high accuracy.Structured meshes are generated in fluid domains,with special treats on fluid-solid walls with heat transfer according to the requirements of turbulence model.The results of pipe-net calculation and conjugate heat transfer analysis are compared,discovering that the flow-net calculation is of lower accuracy and the results of conjugate heat transfer analysis are relatively reliable.One conjugated heat transfer analysis of a certain cooling structure of a blade requires 5 to 15 days,which generally meets the needs of engineering design.
What problem does this paper attempt to address?