Study on municipal wastewater treatment with UASB pilot scale

Yang Qi,Shi Hanchang,Qian Yi
DOI: https://doi.org/10.3969/j.issn.1673-9108.2005.11.018
2005-01-01
Abstract:Municipal wastewater treatment with UASB pilot scale(100 m~3/d) is studied.The results of the experiment indicate: using this system to deal with the municipal wastewater,the quality of effluent water is good.The removal rate of COD is in 52%~83%.The value of COD of effluent water is smaller than 100 mg/L,the removal rate of SS is about 95%.When UASB is used to treat municipal wastewater,the best retention time is 6 hours.The rate of gas production is 0.1 m~3/d.No matter the retention time is 10 hours or 5 hours,the ammonia nitrogen and the values of acetic acid in effluent water are higher than those in influent water.The values of calcium,magnesium,total nitrogen,total phosphorus,both the root of sulfuric acid and root of nitric acid in effluent water are lower than those in influent water.