Correlation Between Perfusion CT Imaging and CD105 Expression in Rat Brain C6 Gliomas

张家文,冯晓源,姚振威,刘含秋,陆娜,邱龙华,杨艳梅,黎元
DOI: https://doi.org/10.3969/j.issn.1005-4847.2013.03.006
2013-01-01
Abstract:Objective To investigate the features of CT perfusion imaging,and analyze the correlation between CT perfusion paremeters and angiogenesis in rat C6 gliomas.Methods In a total of 20 male SD rats,weighting 260-280 g,were divided into the glioma group(n=10) and control group(n=10) at random.Rats in the control group were injected 10 μL normal saline into the right caudate nucleus of the brain using a stereotaxic apparatus.Rats in the glioma group were implanted C6 glioma cells at the right caudate nucleus of brain using the same stereotaxic apparatus to establish a rat brain glioma model.After three weeks,perfusion CT was performed in the rats of both groups.Perfusion CT values of the right nucleus caudatus(CBV,CBF,PS and MTT) were measured.The rats were killed and their brains were removed within 24 hours after perfusion CT,and the tissue samples of nucleus caudatus were examined histologically using HE and immunohistochemical staining for FVIII and CD105.The differences between the number of FVIII-positive vessels within the gliomas and that of normal brain tissues in the control rats were determined using independent samples t test.Pearson correlation coefficients were used to evaluate the relationships between perfusion CT parameters(CBV,CBF,PS and MTT) and immunohistochemical parameters(FVIII-MVD and CD105-MVD).Results All of the rat brain gliomas at 3 weeks after tumor cells implantion showed to be a significantly enhanced mass on contrast enhancement CT scan.The CBV,CBF,PS and MTT values(mean±SD) of the control group were(10.28±4.01) mL/100 g,(304.95±88.77) mL/100 g.min,(0.26±0.34) mL/100 g.min,and(1.48±0.07) s,respectively.The CBV,CBF,PS and MTT values(mean ± SD) of the gliomas at right caudate nucleus area were(17.35±6.73) mL/100 g,(508.66±158.88) mL/min.100 g,(13.92±8.96) mL/min.100 g,and(1.79±0.44) s,respectively.The CBV,CBF and PS values in the glioma group were significantly higher than those in the control group.FVIII-MVD and CD105-MVD in the glioma group were(34.7 vessels per field±7.13) and(16.6 vessels per field±4.12),respectively.Significant correlations were observed between FVIII-MVD,CD105-MVD and CBV,PS in the glioma group.CBF correlated well with CD105-MVD,while CBF was not significantly correlated with FVIII-MVD in the glioma group.MTT results did not show significant correlation with MVD in the glioma group.Conclusion Perfusion CT parameters(CBV,CBF and PS) are significantly correlated with CD105-MVD expression in the rat glioma,and perfusion CT imaging is helpful in research of glioma angiogenesis.
What problem does this paper attempt to address?