Finite Element Analysis of Static Characteristics of Electromagnetic Relay Interfered by Static Magnetic Field

ZHAI Guo-fu,ZHOU Xue,REN Wan-bin
DOI: https://doi.org/10.3321/j.issn:0258-8013.2008.18.023
2008-01-01
Abstract:As the controlling components electromagnetic relays are applied widely in electronic devices and systems,and the electromagnetic compatibility(EMC) between them and other components is important to the reliability of systems.However,electromagnetic relay manufacturers can not give us the EMC characteristics previously.A finite element method(FEM) model of a clap relay under the incident uniform magnetic field from all directions was proposed,and a magnetic vector potential(MVP) method was employed to analyze the static characteristics of relay in incident uniform magnetic field.By numerical analysis with ANSYS,the most susceptive direction of the relay was characterized.Static parameters such as pick-up voltage,release voltage,and the cooperation of electromagnetic torque and spring torque on the armature were calculated,under the interference of magnetic field on that most susceptible direction.This method makes a theoretic basis for analyzing and evaluating electromagnetic immunity to the magnetic interference for electromagnetic relays and electromagnetic relay control systems,and for the manufacturers to rank EMC performance of electromagnetic relay.
What problem does this paper attempt to address?