Abstract:A full-scale research on tourist domestic wastewater treatment by constructed wetland of underflow was conducted in a wastewater treatment plant.In this plant,the average COD of influent is 98 mg/L,and the average COD of effluent is 38 mg/L,meeting the Class 1-A of GB18918-2002,the Integrated Wastewater Discharge Standard of China.In order to achieve the COD of effluent lower than 50 mg/L,the COD of influent to single stage wetlands should be controlled lower than 80 mg/L,while 100 mg/L to two-stage wetlands.The results also showed that underflow constructed wetland is the best choice,compared to upflow and horizon-flow wetlands.In the first stage,the COD removal of reed wetlands and(Arndo) donax L wetland is similar.For the wetlands with different plants in the second stage,the COD removal(sequence) is:(Juncus) effusalinn>canna>cattail>fishscale bamboo>vetiver.