Establishment of an LC-Based Assay to Determine Caffeic Acid Tetramer in Rat Plasma and Its Application to a Pharmacokinetic Study

Yajuan Li,Yuanqing Gu,Junguo Hao,Zhiwen Zhang,Xiaoling Fang,Xianyi Sha
DOI: https://doi.org/10.1365/s10337-009-1175-z
2009-01-01
Chromatographia
Abstract:A facile, sensitive, and accurate liquid chromatographic method with ultraviolet detection was developed for the determination of caffeic acid tetramer in rat plasma. Chromatographic separation was performed on an YMC C18 10 μm column (250 × 4.6 mm) using acetonitrile and phosphate buffer (19:81, v/v ) as mobile phase at a flow rate of 1 mL min −1 . The UV detection wavelength was set at 252 nm. The method showed good linearity in the range of 1–150 μg mL −1 with a satisfactory correlation coefficient ( r ) of 0.997. The limit of detection was 20 ng mL −1 while inter- and intra-day precisions were less than 5.39 and 5.48%, respectively. Furthermore, the accuracy ranged from 98.27 to 103.76% with high extraction recoveries of caffeic acid tetramer from plasma greater than 88.0%. This practical methodology opens a facile and effective pathway for a pharmacokinetic study.
What problem does this paper attempt to address?