Determination of Nimodipine content and related substances in Nimodipine for injection by RP-HPLC

PENG Dong-ming,HUANG Ke-long,LIU Yan-fei,ZHOU Ru-ren
DOI: https://doi.org/10.3969/j.issn.1006-0103.2006.02.035
2006-01-01
Abstract:OBJECTIVE To establish a method for determination of Nimodipine content and related substances in Nimodipine for injection.METHODS Diamonsil~(TM) C_(18) column(250 mm×4.6 mm,5 μm) was used with mobile phase consisted of methanol-water-aether(70∶30∶9) by HPLC.The flow rate was 1.0 ml·min~(-1).The detective wavelength was set at 238 nm.RESULTS The linear range of Nimodipine was 4.0-40.0 μg·ml~(-1)(r=0.9998),The lowest examination limits was 0.376 ng.The average recovery was 99.8%(n=9).CONCLUSION The method is accurate,sensitive and simple.It can be used to determine Nimodipine content and related substances in Nimodipine for injection.
What problem does this paper attempt to address?