Determination of sorbitol and the lower polyols derived from sorbitol hydrogenolysis by high performance liquid chromatography

Zhao Long,Zhou Jinghong,Yang Guang,Ji Yan,Zhou Xinggui
DOI: https://doi.org/10.3969/j.issn.2095-2783.2011.06.004
2011-01-01
Abstract:An HPLC method was developed to determine sorbitol and lower polyols in the product of sorbitol hydrogenolysis using a SHISEIDO CAPCELL PAK C18 AQ column(4.6 mm×250 mm,5 μm) and a refractive index detector,with the conditions of redistilled water as mobile phase,flow rate 0.600 mL/min,the column temperature 25 ℃ and the quantification of compounds was achieved by external standard method.Good linear correlations were showed between the peak areas of sorbitol,ethylene glycol,propylene glycol,glycerol and their concentrations in the concentration range of 0.01% to 1.00%(mass fraction).The correlation coefficients were 0.999 99-1.000 0,with the relative standard deviations(RSD,n=5) in the range of 0.05% to 0.15%.The average recoveries of compounds were 97.65%-101.11% with RSD in the range of 0.55% to 3.60%.This method for determination of sorbitol and the lower polyols in sorbitol hydrogenolysis product is simple,economic and accurate.
What problem does this paper attempt to address?