Urban Energy System Analysis Based on Ecological Footprint Theory

ZHENG Zhonghai,FU Lin,DI Hongfa
DOI: https://doi.org/10.3321/j.issn:1000-0054.2009.12.001
2009-01-01
Abstract:The energy ecological footprint (EEF) of urban energy system was analyzed as a function of the urban and building energy used to promote urban energy usage based sustainable development.The changes in the EEF were calculated for 1990-2007 for each industry in Beijing based on the boundary between the energy supply and energy demand sides. An EEF case study was analyzed for a combined heat and the power system (CHP), a combined cooling,heating and power system (CCHP), and other building energy systems. The results show that the EEF is a good indicator for evaluating urban energy systems. Improvements in the energy use efficiency and reductions of carbon emissions can reduce the EEF for fossil fuel consumption. A reasonable EEF should be 100 times the building area to meet the building energy demand.
What problem does this paper attempt to address?