Design and Study of Rotary Magnetorheological Fluid Testing Device

ZHANG Jin-qiu,ZHANG Jian,KONG Ya-nan,JIA Jin-feng,GAO Yong-qiang
DOI: https://doi.org/10.3969/j.issn.1001-3997.2011.03.019
2011-01-01
Abstract:Based on he broad application of magnetorheological fluid(MRF)and the shortage of testing device of magnetorheological fluid in the market,testing device of magnetorheological fluid is designed and built necessarily to promote the application of MRF.According to theoretic calculation and practical testing,rotary testing device of MRF was designed,and the correctness of magnetic field was verified by experiment.Results showed,when current was 1.6A and magnetic induction was 0.5582T,the shear stress of MRF4 reached to 70.12 KPa;current was 1.4A and magnetic induction was 0.5483T,shear yield stress of MRF4 is 51.6 KPa.
What problem does this paper attempt to address?