Measure for Restraining the Buck Converter's Current Overshooting and the Design of Control Circuit

HAN Ming-wu,HUANG Jun,YANG Shi-yan
DOI: https://doi.org/10.3969/j.issn.1000-100x.2007.01.021
2007-01-01
Abstract:When driving a DC Motor,Buck converter which adopts current close-loop tracking control will result in serious current overshoot easily if there is no effectual measure to be taken,and then the current stress of switches is high.A control circuit is designed to restrain the converter's current overshoot based on the multiplier AD532 by experiments on the ultracapacitor electrical bus.Theoretical analysis and experimental results indicate that the circuit could restrain the current overshoot when starting up or accelerating,then make driving comfortable and make sure that switches work safely.
What problem does this paper attempt to address?