Hemodynamic Variation to Continuous Infusion of Adrenaline (Epinephrine) with Computer Micro Pump During Experimental Cardiopulmonary Resuscitation

ZHONG Qing-ling,LIU Fan-rong,YIN Lin,XIONG J
DOI: https://doi.org/10.3969/j.issn.1000-2294.2007.01.012
2007-01-01
Abstract:Objective To study the effects of continuously administered epinephrine with computer micro pump, on hemodynamic variation during experimental cardiopulmonary resuscitation (CPR).Methods Ventricular fibrillation was induced with epicardium electric current shock in 20 anaesthetised rabbits. The animals were randomized into two groups. One group received three boluses of adrenaline. The other group received an initial bolus of adrenaline followed by an infusion of adrenaline. Aortic systolic pressure(ASP) ,aortic diastolic pressure (AOD),mean arterial pressure(MAP),central venous pressure(CVP),intracranial pressure(ICP) were measured. coronary perfusion pressure(CoPP), cerebral perfusion pressure(CePP),restoration of spontaneous circulation (ROSC) were calculated.Results The data were analyzed with SPSS statistical software. During CPR cerebral perfusion pressure was higher (P<0.05) with a continuous adrenaline infusion than with repeated bolus doses. No differences in CoPP , rate of ROSC, were seen between the study groups.Conclusion Continuous infusion of adrenaline may generate a more sustained increase in CePP during CPR as compared to intermittent bolus doses. Thus, continuous infusion might be a more appropriate way to administer adrenaline as compared to bolus doses during CPR.