Equivalent Circuits Fitting of Electrochemical Impedance Spectroscopy for Corrosion of Reinforcing Steel in Concrete

施锦杰,孙伟
2011-01-01
Abstract:The commonly used equivalent circuits for electrochemical impedance spectroscopy (EIS) testing in reinforcing steel corrosion in concrete have been reviewed,and the advantages and disadvantages of different equivalent circuits were discussed.Appropriate equivalent circuits were selected and analysed for EIS fitting according to the three stages of reinforcing steel corrosion proces,i.e.passivation,corrosion initiation and corrosion propagation.The results indicated that additional time constants may be required with the evolution of reinforcing steel corrosion; moreover,constant phase element(CPE) and Warburg diffusion element were also demanded for best EIS fittings.
What problem does this paper attempt to address?