The influence of different storage time to the blood gas changes of residual blood after cardiopulmonary bypass

Feng Yan,Chen Tao,Chen Hui-min,Feng Jian-yu,Jing Gui-xia
DOI: https://doi.org/10.3969/j.issn.1672-1403.2013.01.003
2013-01-01
Abstract:Objective To investigate the blood gas change of residual machine blood after cardiopulmonary bypass(CPB) at different storage time,and provide a theoretical basis for clinical time limit of the residual machine blood transfusion.Methods The residual machine blood of 80 patients was stored after CPB at room temperature.Then blood samples were taken from the residual machine blood immediately after CPB stoped,and at 30 min,1 h,3 h,6 h and 24 h after CPB to measured the value of kalium(K+),pH,glucose(Glu),base excess(BE),standard bicarbonate(HCO-3) and lactic acid(Lac) with JEM Tremier 3000 automatic blood gas analyzer.Results There was no significant change of K+ concentration in 24 h(P>0.05).With the extention of storage time,PH value gradually decreased(decreased 1.1% after 3 hours and 6.5% after 24 hours,P<0.05),HCO-3 concentration gradually decreased(decreased 12.9% after 3 hours and 26.4% after 24 hours,P<0.01),glucose concentration decreased sharply(decreased 19% after 3 hours and 70.5% after 24 hours,P<0.01),lactic acid concentration increased rapidly(increased 41.2% after 1 hour and 2.8 times after 24 hours,P<0.01),and BE decreased noticibly(decreased 2.467 mmol/L after 3 hours and 7.768 mmol/L after 24 hours,P<0.05).Conclusion The residual machine blood after CPB changed significantly at room temperature with time.In clinical practice,machine blood transfusion should be controlled in 3 hours.
What problem does this paper attempt to address?