Calculation and Analysis of Large-area Soft Ground under Vacuum Preloading

CHEN Ping-shan,MO Hai-hong
DOI: https://doi.org/10.3969/j.issn.1002-4972.2007.12.027
2007-01-01
Abstract:The workload of 3-D FEM calculation of large-scale soft foundation by vacuum preloading is tremendous because of prefabricated vertical drains(PVDs).On a macroscale,the effect of installing PVDs in a subsoil is to increase the mass hydraulic conductivity of the subsoil in the vertical direction.The large-scale ground by vacuum preloading can be transformed to the equivalent foundation by the equation of equivalent permeability coefficient which takes the well resistance and smear effects into account,so the amount of elements will be reduced largely.By means of this method,the 3-D numerical simulation of the test area at Guangzhou Nansha Port is executed,and the results are compared with the test data.It is shown that the 3-D calculation by FEM with the equivalent permeability coefficient is feasible and the calculating precision can meet the requirements of project.
What problem does this paper attempt to address?