Investigating the drug abuse in hair samples with electrospun nanostructure PEDOT-CNT along with EA-IT-SPME
Negar Sabahi Moosavi,Yadollah Yamini,Payam Osooli,Negar Sabahimoosavi
DOI: https://doi.org/10.1039/d4nj00023d
IF: 3.3
2024-03-22
New Journal of Chemistry
Abstract:Electrospinning, as a simple and low-cost method, is one of the best ways to produce nanoscale porous adsorbents. However, electrospinning of pure conductive polymers is not convenient due to their low molecular weight, insolubility in common solvents and the low viscosity of their electrospinning solutions. In this work, electrospinning of conducting polymer to produce poly(3,4-ethylene dioxythiophene)-carbon nanotube (PEDOT-CNT) nanostructure was successfully performed using chemical polymerization of conductive polymer on a skeleton of polyacrylonitrile (PAN). In the next step, the carrier polymer, PAN, was removed so that it did not affect the conductivity of the final product. Conductivity, surface filled with various functional groups, excellent stability and reusability of PEDOT-CNT make it a good choice for electrically assisted in-tube solid phase microextraction (EA-IT-SPME) of drugs abuse from hair samples. Applying the electrical potential increases the extraction efficiency and reduces the extraction time and the volume of desorption organic solvent. The features of the produced nanocomposite were studied by field emission-scanning electron microscopy, energy dispersive X-ray spectroscopy, and Fourier transform infrared spectroscopy. Different influential parameters on the extraction efficiency, such as adsorption potential, time, flow rate, pH, and ionic strength and potential, type, volume and flow rate of desorption eluent, were optimized. Under optimized conditions, the extended linearity for drugs abuse in both water and hair matrices were in the range of 1.0–1000.0 μg L−1, with coefficients of determination more than 0.9922. The limits of detection were also 0.3 μg L−1 in both mediums. This method demonstrated appropriate inter- and intra-day precisions (RSDs, n = 3) in the range of 2.0–3.6% and 3.0–4.7% for water, and 4.0-5.4% and 4.6-6.6% for hair samples, respectively. The application of the method was validated by the analysis of morphine, oxycodone, codeine and naltrexone in human hair as long detection window samples. Finally, acceptable relative recoveries, with no matrix effect disturbance, were calculated in the range of 83.0% to 104.1%.
chemistry, multidisciplinary