Design review on Loukouni bridge in the Republic of Congo considering the difference between Chinese code and Eurocode

WANG Yuan-qing,ZONG Liang,ZHANG Long-ying,JIA Rui-hua,SHI Gang
DOI: https://doi.org/10.3969/j.issn.1672-7029.2012.05.001
2012-01-01
Abstract:Loukouni bridge is a deck type arch bridge with box section which is a part from the second stage of the 1st national road project of the Republic of Congo.General FE software ANSYS was used to have a design review on the bridge to make sure its design is reliable.The design review was implemented based on Chinese code and Eurocode separately.Several results are obtained.The maximum pressure stress of the bridge is about 200 MPa when ultimate limit state is considered.The safety margin of the bridge is proved to be about 1.5.The maximum deflection of the bridge is less than 1/1 000 of length of the calculated span when serviceability limit state is considered.It is proved that the design proposal of the bridge meet the demand in terms of strength and stiffress.Eurocode is more strict in the strength design but weaker at stiffness design than Chinese code.It is suggested that Eurocode is used for initial design and Chinese code is used to check the deflection for the bridges which should meet the demand of these two different codes.
What problem does this paper attempt to address?