Primary Evaluation of an Indirect ELISA for Detecting Hepatitis C Virus Anti-F Antibody

WU Wenbin,SHAO Shengwen,BA Jianbo,QI Zhongtian
DOI: https://doi.org/10.3969/j.issn.1673-8640.2010.10.008
IF: 1.865
2010-01-01
Laboratory Medicine
Abstract:Objective To evaluate the accuracy and reliability of an indirect enzyme-linked immunosorbent assay(ELISA) for detecting antibody to Hepatitis C virus(HCV) F protein.Methods The recombinant HCV F protein was coated in a 96-well microplate as a capture antigen for detecting the anti-F in sera of patients infected with HCV.After the establishment of the cut-off value,the positive rate of anti-F in patients infected with HCV was calculated.Compared with other HCV ELISA kits,the sensitivity,specificity and other parameters of the indirect ELISA were calculated.Results The sensitivity and specificity of the indirect ELISA were 66.7% and 96.7%.The accuracy index was 63.3%,the concordance was 81.7%,and the Kappa value was 0.63.The coefficient of variation(CV) was 6.23%.Conclusions The indirect ELISA meets the requirements of accuracy and reliability.It shows a potential application for anti-F antibody detection in HCV infection as an alternative method.