Dosimetric validation of ~(125)Ⅰ seed implantation in non-small cell lung cancer guided by CT

LI Xiao-dong,GUO Yong-tao,WANG Qin,d H
DOI: https://doi.org/10.3760/cma.j.issn.2095-2848.2006.01.006
2006-01-01
Abstract:Objective To validate the dosimetry of ~(125)I seed implantation in non-small cell lung cancer(NSCLC)guided by CT.Methods ~(125)I seed was implanted in 37 cases confirmed NSCLC by the treatment planning system(TPS)and guided by CT image,then the radiation dose was validated and all ca- ses were fellow up in certain duration.Results Except no response in 2 cases,tumors disappeared in 10 cases and markedly shrinked in 25 cases.The average irradiated absorbed dose by the tumor was 150.5 Gy, whereas the matched peripheral dose(D_(MP))was 86.6Gy,and the irradiated absorbed dose of 90% target volume(D_(90))was 92.4 Gy thus D_(90)>D_(MP).Conclusion The therapy of ~(125)I seed implantation in NSCLC is safe and available.