Effects of High Molecular Polymer Ultrasound Contrast Agents on Ultrasound Imaging of Rabbit

H. Ran,H. Ren,Z. Wang,Y. Zheng,Q. Zhang,C. Xu
DOI: https://doi.org/10.1016/j.ultrasmedbio.2006.02.1291
2006-01-01
Abstract:Objective To explore the effects of the novel high molecular polymer ultrasound contrast agents on enhancing ultrasound imaging and Doppler blood flower signal in vivo experiment.At the same time,experiment was done to explore its safety.Methods Five per cent(mass concentraction) GAOJUXIAN saline water was injected into the ear vein of rabbit((0.25) ml/kg).Vivid 7 color Doppler ultrasound machine with a 12L probe was used to dynamically observe the ultrasound grey scale imaging and Doppler flow signals of rabbits' livers and renals under different mechanic index(MI) and different models,such as harmonic,color Doppler and power Doppler models.And echogenic intensity of the livers was dynamically quantified.Results GAOJUXIAN could enhance the grey scale ultrasound imaging and Doppler flow signals of liver and renal under high or low MI.The enhancement of peak echogenic intensity of the livers after injecting GAOJUXIAN was up to((12.4)±(2.7))dB.The duration of contrast enhancement was longer than thirty minutes.No death or abnormal behaviors of rabbits were observed within two weeks.Conclusions GAOJUXIAN is a kind of safe contrast agents which can enhance ultrasound imaging greatly at different MI and has a long duration time.