A novel hydrogen peroxide sensor based on the direct electron transfer of horseradish peroxidase immobilized on silica-hydroxyapatite hybrid film.

Bin Wang,Jing-Jing Zhang,Zhuang-Ying Pan,Xu-Quan Tao,Huai-Sheng Wang
DOI: https://doi.org/10.1016/j.bios.2008.06.053
IF: 12.545
2009-01-01
Biosensors and Bioelectronics
Abstract:The direct electron transfer of immobilized horseradish peroxidase (HRP) on silica–hydroxyapatite (HAp) hybrid film-modified glassy carbon electrode (GCE) and its application as H2O2 biosensors were investigated. On silica/HRP–HAp/GCE, HRP displayed a fast electron transfer process accompanied with one proton participate in. This sensor exhibited an excellent electrocatalytic response to the reduction of H2O2 without the aid of an electron mediator. The proposed biosensor showed good reproducibility and high sensitivity to H2O2 with the detection limit of 0.35μM. In the range of 1.0–100μM, the catalytic reduction current of H2O2 was proportional to H2O2 concentration. The apparent Michaelis–Menten constant (kmapp) of the biosensor was calculated to be 21.8μM, exhibiting a high enzymatic activity and affinity for H2O2.
What problem does this paper attempt to address?