The Clinical Value of Volume Perfusion Imaging with Dynamic CT in the Solitary Pulmonary Nodules

李慎江,肖湘生,刘士远,李成洲,张沉石
DOI: https://doi.org/10.3969/j.issn.1001-9324.2008.09.020
2008-01-01
Abstract:Objective To evaluate the efficacy of volume perfusion imaging with dynamic CT in the solitary pulmonary nodules (SPNs ).Materials and Methods 85 patients with SPNs (diameter ≤4 cm;57 maliagnant;15 active inflammatory;13benign) underwent multi location dynamic contrast material enhanced (nonionic contrast material was administrated via the antecubital vein by using an autoinjector) serial CT (Toshiba AquilionMarconi 16:4×i transverse scanning mode with stable table were performed;GE Lightspeed 64:8×i or 16×i transverse scanning mode with stable table were performed; i.stands for section thickness).One scan was obtained every 1 seconds during 11~40 seconds without scanning interval after injection,one scan was obtained at 90 seconds.Toshiba Aquilion Marconi 16:the section thickness was 8 mm for lesions 3~4 cm,6 mm for 2~3 cm,4 mm for 1.5~2 cm,3 mm for 1~1.5 cm and 2 mm for lesions 1 cm.GE Lightspeed 64:the section thickness was 8 mm for lesions3~4 cm and 2.5 mm for 3 cm.Precontrast and postcontrast attenuation on every scan and nodules size were recorded.The peak value,perfusion,ratio of peak height of the SPN to that of the aorta and mean transit time of valid sections were calculated.The mean values of valid sections were calculated,as the quantifiable parameters of volume perfusion imaging derived with multislice spiral CT in the solitary pulmonary nodules.Resu-lts Peak heights of malignant(36.52 HU±11.07) and inflammatory (37.69 HU±7.10) SPNs were significantly higher than that of benign (7.02 HU±5.85)SPNs(P0.001;P0.001).No statistically significant difference in the peak height was found between malignant and inflammatory (P=0.6860.05 ).SPN to aorta ratios in inflammatory(17.49%±3.78) SPNs was significantly higher than those in benign(2.78%±2.23) and malignant (14.73%±4.28) SPNs(P0.001;P=0.0190.05).SPN to aorta ratios in malignant SPNs was significantly higher than that in benign SPNs(P0.001).Perfusion values in inflammatory (47.83 ml·min-1·100g-1±31.29)SPNs were significantly higher than those of benign(3.03 ml·min-1·100g-1±3.01) and malignant (31.15 ml·min-1·100g-1±9.66 ) SPNs(P0.001;P0.001).Perfusion values in malignant SPNs was significantly higher than that in benign SPNs(P0.001).Precontrast attenuation of inflammatory (33.00 HU±8.87)and malignant (40.45 HU±7.03) SPNs were lower than that of benign (50.51 HU±10.87) (P0.001;P0.001).Precontrast attenuation of inflammatory was lower than that of malignant (P=0.0020.01).Conclusion The volume perfusion imaging with dynamic CT is helpful in differentiating solitary pulmonary nodules (SPNs).
What problem does this paper attempt to address?