Determination of Two Components in Candesartan Cilexetil and Amlodipine Besylate Combination Tablets

ZHAO Xiao-yan,LI Li
DOI: https://doi.org/10.3870/yydb.2012.09.032
2012-01-01
Abstract:Objective To establish a HPLC method for determination of candesartan cilexetil and amlodipine in their combination tablets.Methods A DIONEX Acclaim 120 C18(250 mm×4.6 mm,5 μm)column was used,with acetonitrile-0.05 mol·L-1 KH2PO4(55:45) as a mobile phase.The flow rate was 1.0 mL·min-1 and detection wavelength was set at 254 nm.Results Candesartan cilexetil and amlodipine had a good linear relationship wthin 19.4-51.8 and 12.5-33.3 μg·mL-1(r≥0.999 7),and the recoveries were 99.1% and 99.3%,respectively.Conclusion The method is simple,quick,accurate and suitable for determination of candesartan cilexetil and amlodipine in their combination tablets.