Evaluation of the diagnostic performance of thyroid‐stimulating immunoglobulin and thyrotropin receptor antibodies for Graves' disease
Shiji Xu,Wenqi Shao,Qun Wu,Jing Zhu,Baishen Pan,Beili Wang,Wei Guo
DOI: https://doi.org/10.1002/jcla.24890
IF: 3.124
2023-05-11
Journal of Clinical Laboratory Analysis
Abstract:This study evaluated the diagnostic performance of TSI for GD and compared it with the validated TBII method. We compared the ROC curve analysis of TRAb and TSI in the GD‐UT and control groups, as well as GD and non‐GD patients with hyperthyroidism. We found that the diagnostic specificity of TSI is lower than that of TRAb, and the positive rate of TSI was higher in TN and AIT patients. Objective To evaluate thyroid‐stimulating immunoglobulin (TSI) and thyrotropin receptor antibodies (TRAb) diagnostic performance for Graves' disease (GD) and determine clinical cut‐off value for diagnosing GD. Methods Of 1369 retrospectively enrolled subjects, 1364 had a definitive diagnosis of untreated GD (GD‐UT, n = 87); treated GD (GD‐T, n = 206); autoimmune thyroid disease (AIT, n = 241); thyroid nodules (TN, n = 677); subacute thyroiditis (ST, n = 28); healthy subjects (HS, n = 125); other diseases with serological hyperthyroidism (n = 5) and were grouped into the following: UT‐GD and control groups (AIT, TN, ST, and HS); and UT‐GD and non‐GD hyperthyroidism groups. Diagnostic performance of TSI and TRAb was evaluated using area under the curve (AUC) of receiver‐operating characteristic (ROC) curve, and optimal clinical cut‐off value was determined using maximization of Youden index. Results TRAb AUC and clinical cut‐off value for diagnosing GD were 0.981 and 1.245 IU/L (sensitivity, 96.6%; specificity, 97.1%; positive predictive value [PPV], 71.8%; negative predictive value [NPV], 99.9%; positive likelihood ratio [PLR], 33.31; negative likelihood ratio [NLR, 0.035), respectively, for the GD‐UT and control groups. Those for TSI were 0.992 and 0.467 IU/L (sensitivity 98.8%; specificity, 96.4%; PPV, 68.8%; NPV, 99.9%; PLR, 27.472; NLR, 0.011). Those for TRAb in GD‐UT and non‐GD hyperthyroidism groups were 0.923 and 1.78 IU/L (sensitivity, 92.0%; specificity, 89.1%; PPV, 93%; NPV, 87.5%; PLR, 8.44; NLR, 0.089), respectively. For TSI, these were 0.92 and 0.545 IU/L (sensitivity, 97.7%; specificity, 83.6%; PPV, 90.4%; NPV, 95.8%; PLR27.472, NLR, 0.011), respectively. Conclusion TSI diagnostic performance for GD was excellent and had better sensitivity than TRAb.
medical laboratory technology