Preliminary assessment of carbon nanoparticles labelling in detection of sentinel lymph nodes in colorectal cancer

FU Jun,YU Bao-ming,BIAN Wei-guo,ZHANG Min,WU Wei-qin
2009-01-01
Abstract:Objective To evaluate the value of sentinel lymph nodes(SLN)in prediction of the celiac lymph nodes status.Methods Carbon nanoparticles were injected into the periphery of the tumor in 50 patients before/during the operation.After 5 minutes,the first black-dyed 1 to 4 lymph nodes were sewed to define as SLN.Then the curative resection were carried out and the samples were examined by pathologist after operation.Results SLNs were found in 47 patients,104 SLNs were identifi ed,the mean number was 2.2.The detection rate of SLN was 94%(47/50);the accuracy was 95.7%(45/47);the specifi city was 93.1%(27/29),the false negative was 10%(2/20)and the negative predictive value was 93.1%(27/29).Conclusion SLN can be easily detected and can precisely predict the celiac lymph nodes status in colorectal carcinoma.The technique of sentinel node biopsy(SNP)may be a part of routine therapeutic tool in management for colon and upper rectal cancer.
What problem does this paper attempt to address?