Abstract:Objective The authors conducted this investigation to evaluate the practicality and performance of restorations generated by Cerec 3D after three years of clinical service.Methods In this pilot study,the authors checked 105 single-tooth,all-ceramic restorations in 99 patients using Cerec 3D,111 Ni-Cr PFM crowns in 108 patients.These crowns were made from 2006.1~2006.8.Results After three years,there was no any statistically significant influence(P0.05) on the clinical performance of the all-ceramic restorations and Ni-Cr PFM crowns on facture of prostheses after three years.The all-ceramic crown was better than Ni-Cr PFM crowns in gingival index(GI),margin sealing and marginal color.Conclusion All-ceramic CAD/CAM-generated restorations are an alternative to conventional restorations.
What problem does this paper attempt to address?