Application of Self-tuning Fuzzy PID in Improvement of Dynamic Characteristics in Pump-Control-Motor System

Shuai LI,Jian-hua WEI
DOI: https://doi.org/10.3969/j.issn.1008-0813.2009.03.006
2009-01-01
Abstract:As a result of oil mixed with air, the system bulk modulus and the leakage coefficient is no longer a constant during the process of pump-control-motor running.The conventional PID controller can't meet the requirement of the dynamic characteristics of the system. In view of above characteristics, the use of self-tuning fuzzy PID in improving the situation has been risen up. The paper analyzed the influencing factor of bulk modulus and leakage coefficient, it also described the method of self-tuning fuzzy PID design. The simulation results show that compared to conventional PID, self-tuning fuzzy PID has faster response and better control performance. Self-tuning fuzzy PID has better adaptability and higher robustness while the mathematic model changing or the system load disturbance.
What problem does this paper attempt to address?