Long-term operation of biofilters for biological removal of ammonia.

Ying-Xu Chen,Jun Yin,Kai-Xiong Wang
DOI: https://doi.org/10.1016/j.chemosphere.2004.09.052
IF: 8.8
2005-01-01
Chemosphere
Abstract:Biological removal of ammonia was investigated using two types of packing materials, compost and sludge in laboratory-scale biofilters (8l reactor volume). The aim of this study is to investigate the potential of unit systems packed with these supports in terms of ammonia emissions treatment. Experimental tests and measurements included analysis of removal efficiency, metabolic products, and results of long-term operation. The inlet concentration of ammonia applied was 20–200mgm−3. The ammonia loading rates of 24.9–566gNH3m−3d−1 to compost biofilter (BF3) and 24.9–472gNH3m−3d−1 to sludge biofilter (BF4) were applied for 210 days, respectively. Removal efficiencies of the compost and sludge biofilters were in the range of 97–99% and 95–99%, respectively when the inlet concentration of ammonia was below 110mgm−3, and the maximum elimination capacities were 288 and 243gNH3m−3d−1, respectively. However, removal efficiency and elimination capacity of both biofilters significantly decreased as the inlet concentration increased to above 110mgm−3.
What problem does this paper attempt to address?