Concentration of Formic Acid Solution by Electro-Electrodialysis

GS Luo,FY Wu
DOI: https://doi.org/10.1081/ss-100102351
IF: 2.799
2000-01-01
Separation Science and Technology
Abstract:The traditional production process for formic acid is a high-energy-consumption process. To save energy when concentrating formic acid solutions, anion-exchange membranes 3362W and AM-203 were evaluated for facilitating the concentration of formic acid solution by electro-electrodialysis. The effects of concentration, temperature. electric current, and time on the electro-electrodialysis process were studied. Experimental results indicated that electro-electrodialysis was an effective method for concentrating formic acid solutions at 30 degreesC. Higher efficiencies were not obtained at higher temperatures. If the concentration of a working system was greater than 10 wt%. The overall current efficiency was greater than 100%. The overall current efficiency was 80-95% when the concentration of a system was less than 10 wt%. In general, the overall current efficiency was increased with an increase of low current density. After a certain value, the overall current efficiency would begin to drop. The performance of the AM-203 membrane was better than the 3362W membrane. With the AM-203 membrane it was found that the overall current efficiency was decreased if the concentration difference between the cathodic and anodic compartments was increased.
What problem does this paper attempt to address?