DHPLC AS A HIGH-THROUGHOUT METHOD FOR MUTATION ANALYSIS

Ying GU,Yan LI,Wei-feng CHEN,Da-qiang YIN,Qing-shun ZHAO
DOI: https://doi.org/10.3321/j.issn:0254-6108.2006.03.019
IF: 4.236
2006-01-01
Environmental Chemistry
Abstract:In this paper,we reported the optimal temperature and sensitivity of denaturing high-performance liquid chromatography(DHPLC) for mutation detection in zebrafish p53 gene fragment containing exon7.Our(results) showed that two point mutated samples determined by sequencing were also detectable by DHPLC.The optimal temperature to detect the point mutation of this fragment is 60℃ and the sensitivity for detecting(molecules) with point mutation is more than 95%.The results indicated that DHPLC can be developed to(detect) the point mutation of zebrafish p53 gene.
What problem does this paper attempt to address?