Dioscin Production Wastewater Treatment by Two-Chamber Microbial Fuel Cells with Different Inoculation

Zhao-fei LI,Hu-chun TAO,Min LIANG,Wei LI,An XUE
DOI: https://doi.org/10.13198/j.res.2009.04.84.lizhf.017
2009-01-01
Abstract:Tests of dioscin production wastewater treatment by two-chamber microbial fuel cells(MFCs) were conducted to compare performance of pollutant removal and power generation under five inoculation conditions.The results showed that the content of organic pollutant in wastewater was cut down and power was generated simultaneously in the MFCs with the wastewater as the substrate.Best efficiency of pollutant removal was achieved using fully mixed inoculation,with a COD_Cr removal rate of 90% after 350 h.Best efficiency of power generation was obtained using mixed inoculation of anaerobic sludge from wastewater treatment plant and culture derived from dioscin production wastewater.An output voltage of 370 mV and maximal power output density of 10.32 mW/m2 were achieved when using a 1,000 Ω external resistor.Different bacteria functioned differently,which contributed to pollutant removal or power generation.Uncultured predominant bacteria strains b,d and e were observed in the tests.Strains d and e were found by PCR-DGGE and DNA sequencing analysis to be similar to β-Proteobacteria.
What problem does this paper attempt to address?