Improving Energy Performance of a Hydrazine Hydrate Plant by Applying Hot Feed

Xiao Feng,Junkun Yang,Taofeng Cao
DOI: https://doi.org/10.1016/s1570-7946(09)70394-3
2009-01-01
Abstract:When analyzing a heat exchanger network, it can be often found, that a given stream is cooled first and then heated or in reverse. In such a situation, one of the available energy-saving methods is a hot feed strategy. In this paper, the heat exchanger network in a hydrazine hydrate plant is analyzed and retrofitted. From the analysis, it can be found that the extensive energy consumption takes place is some coolers above the pinch. Additionally, the product is cooled before leaving the unit, and heated afterwards when entering the downstream plant. By eliminating cooling and the subsequent heating, some streams will be the hot feeds for the downstream processes. In this way, 60.7% of the current heating utility can be saved after the optimization.
What problem does this paper attempt to address?