A Novel Fibula Osteotomy Guide for Mandibular Reconstruction.
Li-Qun Xu,Chen-Ping Zhang,Eugene Hze-Khoong Poh,Xue-Lai Yin,Shu-Kun Shen
DOI: https://doi.org/10.1097/prs.0b013e31824a9e55
2012-01-01
Abstract:Sir:FigureThe greatest challenge in mandibular reconstruction with free fibula grafts lies in contouring the linear fibula into a curved arc resembling the mandible,1 especially for anterior defects where the curvature is the greatest. Absent or severely diseased mandibles preclude the use of prebent reconstruction plates as an osteotomy guide, leaving surgeons to rely on a degree of artistry to arbitrarily determine the location of each fibula osteotomy. Computed tomographic images of the jaws of 55 normal Chinese adults (26 men and 29 women) were used to create virtual mandibular models using Mimics 8.0 software (Materialise, Leuven, Belgium). Five angular and nine linear mandibular variables were established and measured across various cephalometric landmarks and compared with standard t tests and generalized liner model variance analyses. All linear variables demonstrated statistically significant differences with larger standard deviations, whereas angular variables were not significantly influenced by sex differences and had a smaller coefficient of variation. Similarly, the anterior mandible variables had smaller standard deviations and larger p values (Table 1). As the intermental length (Men-Men′) was determined by both the symphyseal angle (Men-Pg-Men′ angle) and the mental to midline lengths (Men-Pg), three key parameters were used for the design of the fibula osteotomy guide: Men-Pg, Men-Pg-Men′ angle, and Go-Men-Pg angle (mental angle). The upper limit of the Men-Pg-Men′ angle's SD value (120 degrees) was selected to allow minor adjustments of the neomandible width, together with the median values of Men-Pg (30 mm) and the Go-Men-Pg angle (140 degrees).Table 1: Definition and Statistical Analysis of the Linear and Angular Variables in the Anterior and Posterior MandibleThe results indicated that a four-segment fibula graft optimally replicated the mandibular contour.2 This required three wedge-shaped fibula osteotomies whereby the internal angulations of the middle and lateral osteotomies corresponded respectively to the Men-Pg-Men′ and Go-Men-Pg angles, and each lateral osteotomy was 30 mm from the middle one to represent Men-Pg. Using an estimated height of 14 mm for a normal human fibula, the inner lengths of both Men-Pg segments were calculated to be 16 mm each. These parameters were then translated onto a C-shaped titanium receptacle with six tangential slots dictating the locations and angulations of each osteotomy. The four remaining fibula segments were then reassembled by means of a “closed-wedge” technique to achieve a continuous, gap-free arc that maximized the cross-sectional contact between the segments for a superior bony union (Fig. 1).Fig. 1: Design of the fibula osteotomy guide (FOG) model to produce four fibula segments that closely replicated the curvature of the mandible following their reassembly. a, half of the Men-Pg-Men′ or Go-Men-Pg angle; i, half the length of each wedge-shaped osteotomized segment; h, height of the fibula osteotomy guide device; tga, tangent of angle a.The absence of a symphyseal angle in three-segment reconstructions invariably causes a squarish appearance and a loss of chin projection. Its proponents argue that despite the superior cosmesis accorded by multiple segments, they were more technically challenging, with an increased risk of devascularization from direct pedicle truncation or excessive periosteal stripping.3 Thus, the fibula osteotomy guide's guiding slots were purposefully designed short of the edge to protect the vascular pedicle from accidental transection (Fig. 2). Each Men-Pg segment would also have a 16-mm-long inner surface abutting the vascular pedicle, in accordance with Bähour's recommendation that a minimal segment length of 15 mm was required for graft survivability.4 Although wider studies are needed to validate its efficacy, the fibula osteotomy guide has proved to be an effective, easy-to-use device that accurately replicated the contour of the anterior mandible.Fig. 2: The six angulated slots of the fibula osteotomy guide determine the position and angulation of each osteotomy. The slots were just short of the edge to protect the vascular pedicle along the fibula's inner surface from accidental transection.Li-qun Xu, D.D.S., M.D., Ph.D. Chen-ping Zhang, M.D., D.D.S., Ph.D. Department of Oral and Maxillofacial Surgery, College of Stomatology, Shanghai Ninth People's Hospital, Shanghai Jiao Tong University, Shanghai Key Laboratory of Stomatology, Shanghai, People's Republic of China Eugene Hze-Khoong Poh Oral and Maxillofacial Department, Khoo Teck Puat Hospital, Singapore Xue-lai Yin Shu-kun Shen Department of Oral and Maxillofacial Surgery, College of Stomatology, Shanghai Ninth People's Hospital, Shanghai Jiao Tong University, Shanghai Key Laboratory of Stomatology, Shanghai, People's Republic of China DISCLOSURE The authors have no potential conflict of interest to declare. ACKNOWLEDGMENTS This work was supported by the Science and Technology Commission of Shanghai Municipality (10142201500) and Shanghai Jiao Tong University Medical-Engineering Research Fund (YG2009MS41).