Resolution of Transverse Electron Beam Measurements Using Optical Transition Radiation

R Ischebeck,FJ Decker,M Hogan,RH Iverson,P Krejcik,RH Siemann,D Walz,M Lincoln,CE Clayton,CK Huang,W Lu,SZ Deng,E Oz
DOI: https://doi.org/10.1109/pac.2005.1591710
2005-01-01
Abstract:In the plasma wakefield acceleration experiment E-167, optical transition radiation is used to measure the transverse profile of the electron bunches before and after the plasma acceleration. The distribution of the electric field from a single electron does not give a point-like distribution on the detector, but has a certain extension. Additionally, the resolution of the imaging system is affected by aberrations. The transverse profile of the bunch is thus convolved with a point spread function (PSF). Algorithms that deconvolve the image can help to improve the resolution. Imaged test patterns are used to determine the modulation transfer function of the lens. From this, the PSF can be reconstructed. The Lucy-Richardson algorithm is used to deconvolute this PSF from test images.