Rapid detection of coliforms in dairy using test strip

DUAN Xue-hui,WEI Bin,FU Qi,GUO Bing-qi,JIA Kui-yan
DOI: https://doi.org/10.3969/j.issn.1001-2230.2011.01.010
2011-01-01
Abstract:In this study,a rapid and simple method for detection the total coliforms in dairy,fixing optimal nutrient including basic nutrition and supplementary nutrition,indicating agent,buffering agent,specific bacteriostatic agent on the designed strip through cold gel was investigated.Based on strip color change,coliforms can be quantitatively reported as MPN,and the overall assay time only needed of 16-18 hours.The conditions of the detection such as the species of cold gel and proportion of medium,as well as the concentration of indicating agent and buffering agent were studied.This method was compared to the multiple-tube fermentation using calibration of standard strain for the analysis of samples,the rapid test strip showed low detection limit of 0-4 cfu/mL.A high agreement(96.7%) was found between rapid test strip and standard on 60 commercial dairy samples.No significant difference(p>0.05) was found between the detection results for the methods.The test strip method was cost-effective,simple,rapid and accurate,can be used to detect coliforms in dairy.
What problem does this paper attempt to address?