Analysis of Reasons for Inner Opening in Inside Cylinder of 600 MW Supercritical Steam Turbine

DENG Shi-rui,WANG Shi-chao,ZHANG Qiang,XIN Jian-hua
2010-01-01
Abstract:The thermal field and stress field were calculated for the HP and IP cylinder of 600 MW supercritical steam turbine in one integral star-stop process with the finite element software of ANSYS.The results showed that the temperature difference between the inner and outer walls of the HP and IP cylinder was more than 80℃,which caused the basis thermal stress higher than 220MPa when the turbine was in high load operation.By analyzing the start data,it was found that the main reason for the excessive temperature difference between the inner and outer walls was that a small amount of HP cylinder exhaust directly leaked into the three pumping of IP cylinder through the interlayer between the inner and outer cylinders which directly cooled the outer wall of the inner cylinder.Analyzing and solving the leakage problem can lower the basis thermal stress in the operation process and avoid further widening of inner opening.On the other hand,it can also improve the efficiency of the unit.
What problem does this paper attempt to address?