Effect of Drug-Eluting Stent and Bare Metal Stent in Small Coronary Arterial Lesions

Zhang Qing,Ge Heng,Han Zhihua,Li Jinhua,Wang Binyao,He Ben
DOI: https://doi.org/10.3969/j.issn.1672-4194.2007.03.012
2007-01-01
Abstract:Objective To compare the acute and long-term outcomes of patients treated with Sirolimus-eluting stents(SES) and those implanted with bare-metal stents(BMS) in small coronary arteries at a high volume cardiac center. Methods We retrospectively compared consecutive 448 patients who underwent SES implantation in small coronary arteries and 124 patients who received conventional BMS. The SES and the BMS placements were available in diameters of 2.25, 2.5, and 2.75 mm. In-hospital and 9-month follow-up of major adverse cardiac events(MACE) were evaluated. Results Compared with the BMS group, implanted SES had larger mean diameter and length. 9-month follow-up showed that the angiographic restenosis rate was significantly lower in the SES group than those of the BMS group(1.60% vs 9.90%, P<0.001). The overall rate of MACE was 4.30% in the SES group and 13.9% in the BMS group (P<0.001). Conclusion Compared with BMS, SES implantation in small coronary arteries is effective and associated with a marked reduction in restenosis rate and the need for subsequent target lesion revascularization at nine months.