Application of Anti-HCV Detection Method Kit in Risk Population ZHANG

张贺秋,王国华,陈坤,宋晓国,冯晓燕,修冰水,何竞,朱翠侠
DOI: https://doi.org/10.3969/j.issn.1671-2587.2008.02.001
2008-01-01
Abstract:Objective The sensitivities and specificities of two commercial available kits,anti-HCV detection method (double antigen sandwich) and indirect detection method (ELISA) were compared in risk population.Methods 85 samples were collected in Gu′an of Hebei province which was the high-risk area of HCV. All of the samples were detected by anti-HCV detection kit (double antigen sandwich) and indirect detection kit. The inconsistent samples were detected again by HCV-RIBA supplementary reagent.Results Among the 85 samples,76 positive samples (89.41%) and 9 negative samples were detected using indirect method,while 73 positive samples (85.88%) and 12 negative samples were detected using anti-HCV double antigen sandwich detection method. 3 samples that were weak positive by indirect detection method and that were negative by sandwish detection method. There was only one sample with one line was detected by HCV-RIBA kit. The virus load was (1.2~4.8)×102 copies/ml, which was HCV RNA negative.Conclusion In risk population, the sensitivities of the two methods are the same, but the specificity of the anti-HCV double antigen sandwich detection method is better than that of the indirect detection method.
What problem does this paper attempt to address?