Effect of Particle Size on Water Treatment Performance of the Bipolar Pulsed Discharge

CHENG Xing-xin,ZHANG Chi,ZHANG Ruo-bing,JIA Zhi-dong,WANG Li-ming,GUAN Zhi-cheng
DOI: https://doi.org/10.13336/j.1003-6520.hve.2008.02.002
2008-01-01
Abstract:Effect of glass beads size on dyeing waste water treatment performance was investigated by using bipolar pulse treatment system, and the influence of gas flow rate was studied simultaneously. UV-Vis absorption spectrum was used as the analysis method. The results show that packing of glass beads into the reactor effectively enhances water treatment performance of the system; water treatment system has a higher color removal efficiency when diameter of glass beads is in the window of 6~9 mm in size. The farther the particle size deviated from this range, the worse the performance would be. In addition, gas flow rate has little effect on treatment performance if the particle size is in the size window, while out of the window, decolorization rate of the system increases as the gas flow rate increased from 0.5 m3/h to 1.0 m3/h.
What problem does this paper attempt to address?