Evaluation of pulmonary function by low-dose dual-phase CT scanning in patients with chronic obstructive pulmonary diseases

WANG Xiao-hua,DUAN Jiang-hui,DU Yi-peng,SHEN Ning,Bei HE,YUAN Hui-shu
DOI: https://doi.org/10.3969/j.issn.1006-5725.2013.20.015
2013-01-01
Abstract:Objective To evaluate the value of low-dose dual-phase CT scanning in evaluating the pulmonary function of patients with chronic obstructive pulmonary disease(COPD). Methods 44 patients with COPD(COPD group) and 15 normal controls(control group) received low-dose dual-phase CT canning within one week after pulmonary functional test(PFT), then the CT data were obtained during breath hold at full inspiration and full expiration. The lung volumes, air trap and percentage were determined by Lungs quantitative software(GE); and then their correlation with PFT index was analyzed. Results The total lung capacity at full inspiratory and expiratory(Vin, Vex), air trap(Vtrap) and percentage(Vtrap%) at full expiratory phase in COPD group were significantly higher than those in control group(P < 0.05). There was positive correlations between Vin and total lung capacity(TLC)(r = 0.675, P < 0.01), and between Vex and residual volume(RV)(r = 0.651, P < 0.01);and negative correlations were found between Vtrap, Vtrap% and FEV1 / FVC(r =-0.506 and-0.602, P < 0.05and P < 0.01, respectively). Conclusion Low-dose dual-phase CT scanning had good value in evaluating pulmonary function of patients with COPD.