The role of nuchal translucency in prenatal screening

WEI Yuan,YANG Zi,LIU Zhao-hui,YE Zhen-ya,ZHAO Shu-ying
DOI: https://doi.org/10.3969/j.issn.1006-9534.2006.07.034
2006-01-01
Abstract:Objective:To establish the standard value range of fetal nuchal translucency(NT)in deferent gestational week and to investigate the role of NT measurement in the screening of fetal malformation.Methods:A total of 959 pregnant women underwent NT screening from November 2003 to April 2005 in Peking University Third Hospital.The cut-off value of risk for trisomy 21 is over 3mm from 10~14 gestational weeks,and 5mm after 14 gestational weeks.Fetal outcomes were evaluated.Results:An elementary referential parameter of the fetal nuchal translucency from 12 to 14 Gestational weeks was obtained.NT was increased with gestational week.The regression equation was NT=0.0229×(gestation week)-0.1021,(r=0.0229,P<0.01).No difference was found with pregnant age.Taking 3mm as the risk cutoffs,the false negaive rate was zero and with a 100% positive rates;taking 2.5mm as cut-offs,the false positive rate was 4.3% with a positive rates of 100%.There were 5 abnormal fetuses with a thick NT.Conclusion: The nuchal translucency measurement by ultrasonograph is a useful method in prenatal screening and diagnosis.There is a relationship not only with chromosome abnormality,but also with other fetal mslformation.
What problem does this paper attempt to address?