Enantiomeric Separation of Terazosin by NP-HPLC

LIU Man,ZHANG Dan,HAN Jing,LIU Huichen
DOI: https://doi.org/10.3969/j.issn.1001-8255.2012.01.015
2012-01-01
Abstract:A NP-HPLC method was established for the enantiomeric separation of terazosin.Baseline chiral separation of terazosin enantiomers was achieved under normal-phase mode using the Chiralpak AD-H chiral column.The influences of the composition of the mobile phase,the flow rate and column temperature on the enantiomeric separation were investigated.The optimal chromatographic conditions were hexane-isopropyl alcohol-diethylamine(65︰35︰0.1) as the mobile phase at the flow rate of 0.7 ml/min and the detection wavelength of 254 nm at the column temperature of 25 ℃.The resolution between the peaks of terazosin enantiomers was 3.1 under the above chromatographic conditions.The calibration curves of terazosin enantiomers were linear in the concentration range of 2.5-7.5 μg/ml.The average recoveries were 99.8% and 99.4%,with RSDs of 0.44% and 0.42%.
What problem does this paper attempt to address?