Numerical Simulation on Temperature Field Inside Sealed Battery Chamber

LI Wei,SONG Bao-wei,HU Yu-li
DOI: https://doi.org/10.3969/j.issn.1673-1948.2011.04.013
2011-01-01
Abstract:When a Li-ion battery bank discharges continuously at large power inside a sealed battery chamber for a long time,much heat energy will be produced and accumulated,which may cause batteries leaking,metamorphosing,ex-ploding,and so on,and further decrease the efficiency and safety of the battery bank.So it is necessary to investigate the temperature field inside the chamber.This paper establishes a finite element model with the software ANSYS to simu-late the temperature field distribution inside the battery chamber of an underwater vehicle.Simulation result indicates that the maximum temperature is lower than the critical temperature of 150 ℃ when the battery bank discharges for 2.5 hours at 40 A.
What problem does this paper attempt to address?