Comparative Analysis of Quantitative Method on Heavy Metal Detection in Water with Laser-Induced Breakdown Spectroscopy

Wang Chun-Long,Liu Jian-Guo,Zhao Nan-Jing,Ma Ming-Jun,Wang Yin,Hu Li,Zhang Da-Hai,Yu Yang,Meng De-Shuo,Zhang Wei,Liu Jing,Zhang Yu-Jun,Liu Wen-Qing
DOI: https://doi.org/10.7498/aps.62.125201
IF: 0.906
2013-01-01
Acta Physica Sinica
Abstract:The quantitative analysis models of multiple linear regression, neural network regression and support vector machine regression with laser-induced breakdown spectroscopy are established in this paper. Heavy metal Ni in water selected as research object is tested and comparativly analyzed. The average relative standard deviations of multiple linear regression, neural network regression and support vector machine regression are 7.60%, 4.86% and 2.35%, and the maximum standard deviations are 23.35%, 15.20% and 8.29% respectively, the average relative errors are 25.98%, 10.58% and 2.72%, and the maximum relative errors are 116.47%, 47.38% and 9.89% respectively. Methods and reference data are provided for the further study of fast measurement of tracing heavy metals in water by laser induced breakdown spectroscopy technique.
What problem does this paper attempt to address?