Study on performance of air cleaner to remove formaldehyde by continuous mode

Wang Juan,Zhang Pengyi,Zhang Lin
2011-01-01
Abstract:Continuous test mode was used to evaluate the capability of air cleaner A by water absorption-indirect degradation and air cleaner B which with activated carbon filter to remove formaldehyde,to explore more scientific and reasonable methods for evaluating the air cleaners to remove gaseous pollutants.The air cleaner A showed significant capability to remove formaldehyde from air of initial formaldehyde concentrations of 0.3,0.5,0.8 or 1 mg/m3 in continuous mode,and the corresponding removal rates ranged from 0.91 to 2.78 mg/h.The removal rate of the air cleaner A decreased gradually with operation time.However,it recovered and kept long term capability to remove formaldehyde if water could be timely replenished into the electrolysis water bath of the air cleaner.The air cleaner B lost its capability to remove formaldehyde within 30 h in continuous mode.Continuous mode could more scientifically and reasonably evaluate the capability of air cleaners to remove gaseous pollutants,especially their long term capability.