Oxidative Desulfurization of RFCC Diesel Fuel

LI Ruili,LIU Ying,LI Bo
DOI: https://doi.org/10.3969/j.issn.1000-6613.2013.08.016
2013-01-01
Abstract:Sulfur compounds of RFCC diesel oil were removed by using H2O2-formic acid as oxidant and DMF as extractant. The effects of oxidation time,oxidation temperature,H2O2 dosage and formic acid dosage on desulfurization efficiency were studied. The effect of dispersant Span-80 on desulfurization efficiency of oxidation with H2O2-formic acid were also investigated. The optimal oxidation conditions of H2O2-formic acid-Span-80 were mass fraction of Span-80 dispersant 2.0%, volume fraction of H2O2 oxidant 36%,volume fraction of formic acid 32%,oxidation temperature 60 ℃,oxidation time 50 min. Desulfurization rate was increased from 85.58% to 98.27% by Span-80 dispersant. The sulfur content of RFCC diesel fuel could be lowered from 12500 mg/L to 216 mg/L. According to GC analysis,the removals of thiophene,benzothiophene and its derivatives were almost complete,and further efforts are needed to remove dibenzothiophene and its derivatives.